Analisis Pengaruh Intensitas Pencahayaan Di Laboratorium Pengujian Terhadap Akurasi Pengujian

Authors

  • Tri Ernita Sekolah Tinggi Teknologi Industri Padang Author
  • Boby Rachman Author
  • Henny Yulius Author
  • Sastri Author

DOI:

https://doi.org/10.52759/inventory.v6i2.75

Keywords:

Lighting Intensity, Testing Accuracy, Testing Laboratory, Correlation Analysis

Abstract

The testing laboratory is a high-precision testing room that reguires adeguate environmental conditions for testing needs.As a testing laboratory, it is important for the banten Indonesia Laboratory to control the laboratory's environmental conditions, one of which is lighting intensity.Inadeguate lighting intensity can reduce testing accuracy, Currently, the average lighting intensity in the banten Indonesia Laboratory  is  370 lux, this value is below the regulatory standard Threshold value, which according to PERMENKES NO. 70 of  2016 for standard laboratories lighting intensity is 500 lux. This study aims to increase lighting according to SNI 7062:2019 and  testing accuracy in the Banten  Indonesia Laboratory and to determine how strong the relationship  betwen lighting intensity and testing accuracy is using correlation analysis with SPSS V.27. The results of this study indicate that lighting intensity has increased to 489 lux and the average accuracy has increased by 7.5 % after changing the lamp,in addition,the relationship between lighting intensity and testing accuracy strong ,this is evidenced by the result of the correlation analysis obtained a significance value of 0.620 and 0.627 .

Downloads

Download data is not yet available.

References

Nasional, B. S. (2017). Standar Nasional Indonesia Persyaratan umum kompetensi laboratorium pengujian dan kalibrasi General requirements for the competence of testing and calibration laboratories. In IEC (Vol. 17025). www.bsn.go.id

Putri, S. I., & Sudarti, S. (2022). Analisis Intensitas Cahaya di Dalam Ruangan dengan Menggunakan Aplikasi Smart Luxmeter Berbasis Android. Jurnal Materi Dan Pembelajaran Fisika, 12(2), 51. https://doi.org/10.20961/jmpf.v12i2.51474

Rachmat, A. N., Santoso, M. Y., & Zakaria, R. (2023). Analisis Nilai Pengukuran Penerangan pada Laboratorium Ergonomi sesuai Permenaker No 05 Tahun 2018. G-Tech: Jurnal Teknologi Terapan, 7(2),422–428. https://doi.org/10.33379/gtech.v7i2.1998

Syamsi, W. A., Setianto, N., Saepuloh, A., & Suyono, A. M. (2024). Analisis Intensitas Cahaya Di Laboratorium Pt X Metode Sni 7062:2019. Jurnal Ilmiah Teknik Dan Manajemen Industri Jurnal Taguchi,4(1),163–170. https://doi.org/10.46306/tgc.v4i1

Tegar, F., Alawiyah, R., Hikmah Dilla Jannah, K., Adi Jaya Pohan, A., Mardyanti Purba, N., Hasanah, N., Anggraini Nasution, D., & Niswati Utami, T. (2023). Pengaruh Intensitas Paparan Cahaya Terhadap Kelelahan Mata Pada Pekerja Home Industri. Ilmiah Mahasiswa Pendidikan Sejarah, 8(3),2035–2045. https://doi.org/10.24815/jimps.v8i3.25616

Yudha Asmara, I., Garnida, D., & Hilmia, N. (2023). Korelasi Intensitas Cahaya Dengan Karakteristik Suara Ayam PeluNG (Correlation Of Light Intensity and Sound Characteristics of Pelung Chickens). 49, 2024–2376.

Downloads

Published

2026-02-19

Issue

Section

Articles